– Ozone Chemical Detection Devices

Detect Ozone on the Job Site

Ozone is a bluish gas with a pleasant, characteristic odor in concentrations less than 2 ppm. In higher concentrations, the odor is pungent and irritating. Ozone is used as a disinfectant for air and water. It is also used to bleach waxes, textiles and oils.

Ozone is a severe irritant to the eyes and the mucous membranes. Long-term exposures to ozone can cause pulmonary edema (abnormal fluid buildup in the lungs) and chronic respiratory disease.

How can Morphix Technologies help?

ChromAir® and SafeAir® Ozone badges are simple, cost-effective, industry-proven solutions for ozone detection in the workplace. These badges use colorimetric technology (i.e. color change) to provide immediate indication when ozone is present. No need for lab analysis or electronic reader.

Ozone detection in use

Badges Designed for Ozone Detection

SafeAir Ozone Badge

SafeAir Ozone Badge product photo
  • Detects presence of ozone using a universal warning sign (exclamation mark in triangle)
  • Ideal for employee monitoring or leak detection
More About SafeAir Ozone

ChromAir Ozone Badge

ChromAir Ozone Badge product photo
  • Indicates range of exposure dose to ozone using an easy-to-read format
  • Ideal for employee or area monitoring
More About ChromAir Ozone

Badges designed for Ozone detection

– Product Details

SafeAir Ozone Badge (Part#: 382004)

Designed for effective ozone monitoring

SafeAir Ozone badges provide an immediate visual indication of exposure to ozone. When ozone gas is present, the exclamation mark in the triangular window changes color.

The intensity of the color change is proportional to the exposure dose.

Key Features of the SafeAir® Ozone Detection Badge:

  • Accurate ozone detection using colorimetric technology
  • Immediate visual response—no electronic reader or lab testing required
  • Cost-effective
  • Lightweight
  • Easy to use

Available to US customers on Amazon.com

International customers, please contact us using the information below.

Contact Now

Click here for operating instructions for SafeAir Ozone detector badges.

Employee Monitoring

An employee wears badge near their breathing zone

Employee Monitoring

Leak Detection

Place badge near the source of potential leak

Leak Detection

** Badge Clips Sold Separately.

Physical SpecificationsValue
Dimensions74 mm x 41 mm x 1mm
Weight1.5 g
Color changeBlue to white
Refrigerated shelf life1 year
Sampling ParametersValue
Exposure level0.05 ppm • hr
Minimum detectable limit (8 hours)0.006 ppm
Maximum recommended sampling time48 hours
Minimum recommended sampling time15 minutes
Relative humidity range30% - 80%
Face velocity range10 – 150 cm/sec
Temperature range15°C - 32°C (60°F - 91°F)
Light effect – UV (direct sunlight)not recommended
Light effect – visibleno effect
Color stability4 weeks
Known interferencesHydrogen peroxide, and nitrogen dioxide up to 1 ppm

By Phone:

+1-757-431-2260

For customers outside the US, email or call to be referred to a distributor.

Available on Amazon (for US customers)

Available on Amazon

Available on GSA (for US government customers)

GSA Advantage

GS-07F-0147T (Laurus Systems, Inc.)

– Product Details

ChromAir Ozone Badge (Part#: 380010)

ChromAir Ozone badges provide an immediate visual indication of exposure dose for chlorine.

When exposed to ozone, a color change forms, starting from the bottom, climbing up to the top in six cells.

The highest cell with a color change indicates dose exposure level.

Key Features of the ChromAir® Ozone Detection Badge:

  • Accurate ozone detection using colorimetric technology
  • Immediate visual response—no electronic reader or lab testing required
  • Cost-effective
  • Lightweight
  • Easy to use

Available to US customers on Amazon.com

International customers, please contact us using the information below.

Contact Now

Click here for operating instructions for ChromAir Ozone detector badges.

Employee Monitoring

An employee wears badge near their breathing zone

Employee Monitoring

Area Monitoring

Hang badge for area monitoring

Area Monitoring

** Badge Clips Sold Separately.

Physical SpecificationsValue
Dimensions10.5 cm x 5.5 cm x 0.25 cm
Weight11 g
Refrigerated shelf life1 year
Color changeBlue to white
Sampling ParametersValue
Exposure Dose Range0.08 – 1.6 ppm • hr
Maximum recommended sampling time10 hours
Minimum recommended sampling time5 minutes
Relative humidity range20% - 90%
Face velocity range10 - 165 cm/sec
Temperature range16ºC - 30ºC (61ºF - 86ºF)
Light effect - UV (direct sunlight)not recommended*
Light effect - visibleno effect
Known interferenceshydrogen peroxide, and nitrogen dioxide up to 1 ppm

*The back of the badge (viewing area) should not be exposed to direct sunlight at any time.

By Phone:

+1-757-431-2260

For customers outside the US, email or call to be referred to a distributor.

Available on Amazon (for US customers)

Available on Amazon

Available on GSA (for US government customers)

GSA Advantage

GS-07F-0147T (Laurus Systems, Inc.)

– Frequently Asked Questions –

FAQ

Where is ozone used?

Ozone is used as a disinfectant for both air and water. It can also used to bleach waxes, textiles, and oils.

What are the health effects of ozone exposure?

Ozone is a severe irritant to the eyes and the mucous membranes. Long-term exposures can cause pulmonary edema (abnormal fluid buildup in the lungs) and chronic respiratory disease.

What are the exposure limits for ozone?

OSHA and NIOSH exposure limit for ozone is 0.1 ppm (TWA).

How does an ozone badge change color?

A color-forming reaction occurs when ozone reacts with the proprietary indicator layer in SafeAir and ChromAir ozone detector badges.

– Get in Touch –

Contact Us